FULLCHANCE FIRE-GUARD

Fullchance Fire Guard is specifically developed for military applications such as Battle Ships and Submarines where fire safety standards are absolutely critical. The Fire-Guard floorings have benefits with regard to quality & functionality which the specific demand made on floor coverings for interior use in passenger liners / ferries, cruisers, tankers, container ships and marine ships world-wide. The Fire-Guard floorings are also used in underground metro rails as fire safety is an important factor in underground rail lines. These floorings have a fire rating of class 0 which have been tested and approved by Warrington Fire Labs U.K.

 

Fullchance Fire Guard Rubber Flooring is available in fabric finish.

 
 

Benefits of Fullchance Fire Guard

  1. Extremely long life.

  2. Extraordinary wear-resistant.

  3. Anti-slip properties.

  4. Excellent fire-protection properties.

  5. Resistant to cigarette burns.

  6. Largely resistant to chemicals.

  7. High level of footfall sound absorption.

  8. Permanently resilient with a high walking comfort.

  9. Easy and economic cleaning.

 

Technical Specification

  • Fire Propagation to BS 476 prt 6.

  • Surface Spread of flame to BS 476 prt 6.

  • Ignitability to BS 476 prt 12.

  • Reaction to fire: BS ISO 9239-1.

  • Smoke Density to BS 6853:1999 Annx D

  • Smoke Toxicity to BS:6853:1999 Annx B

  • Temperature Index to BS 6853:1999 Appx A

  • Slip Resistance to SATRA PM 144.

  • Light reflectance > 35%.

  • Abrasion resistance to DIN 53 519.

  • Graffiti resistance to E6264.

  • Chemical resistance to E6264.

  • Lightfastness to E6264 E2.

  • Spec. gravity to BS 903 prt A2.

  • Hardness to BS 903 prt A1.

  • Tensile strength to BS 903 prt A2.

  • Elongation to BS 903 prt A2 plain.

  • Chemical resistance to BS 905.

  • Smoke Index to NES 711.

  • Toxicity index to NES 713.

  • Oxygen index to NES 714.

  • Temperature index to NES 715.

 

Product Availability

  • Thickness: 2mm, 2.5mm, 3mm & 4mm.

  • Rolls.

  • Available in a range of colours.

 

Typical Applications

  • Aircraft Carriers.

  • Frigates.

  • Survey vessels.

  • Submarines.

  • Military Application.

 

Speckles


DT SP CL-0 -001 ROYAL BLUE

DT SP CL-0 -002 SEA GREEN

DT SP CL-0 -003 MHAGONI
     

DT SP CL-0 -004 DARK GREY

DT SP CL-0 -005 BLACK

DT SP CL-0 -006 LIGHT GREEN
     

DT SP CL-0 -007 LIGHT TAN

DT SP CL-0 -008 LIGHT GREY

DT SP CL-0 -009 OLIVE GREEN

Fullchance FIRE-SAFE

Fullchance Fire-Safe is a custom made range of synthetic rubber floor coverings. Each color and surface finish selected by the customer to meet their own specific requirements or corporate color schemes. It is designed to meet the requirements of both single and multi-track railway systems confirming to BS 6853:1999 cat 1a and 1b.

 

This Flooring is recommended for high traffic areas where higher safety standards are required. This flooring is flame resistant and comes with a M1 (Class 1) classification tested at Warrington Fire UK. Fullchance Fire-Safe is available in plain, speckle or marble Finishes.

 
 

Technical Specification

  • Surface spread of flame to BS 476Pt7

  • Smoke Test to BS 6853:1999 D8.6

  • Toxicity Test to BS 6853:1999 B4.2

  • Fire Behavior to BS 6853:1999

  • Fire Behavior to BS 476 Pt 6

  • Slip Resistance to SATRA TM 144

  • Slip Resistance to BS 7976-2 2002

  • Abrasion Resistance to ASTM D4060

  • Abrasion Resistance to DIN 53 516

  • Specific Gravity to DIN 53 508

  • Hardness to DIN 53 505

  • Tensile strength to DIN 53 504

  • Elongation to DIN 53 504 (Plain)

  • Graffiti Resistance to E6264

  • Chemical Resistance to E6264

 

Product Availability

  • Thickness: 2mm, 2.5mm, 3mm & 4mm.

  • Rolls.

  • Available in a range of colours.

 

Typical Applications

  • Single and multi-track underground trains

  • Underground stations .

  • Driver less trains.

 

Speckles


DT SP CL-1 -001 ROYAL BLUE

DT SP CL-1 -002 SEA GREEN

DT SP CL-1 -003 MHAGONI
     

DT SP CL-1 -004 DARK GREY

DT SP CL-1 -005 BLACK

DT SP CL-1 -006 LIGHT GREEN
     

DT SP CL-1 -007 SAND YELLOW

DT SP CL-1 -008 LIGHT GREY

DT SP CL-1 -009 OLIVE GREEN

FULLCHANCE FIRE-SHIELD

Fullchance Fire Shield is available in a wide range of colours.

 

Fullchance Fire Shield is also appropriate for the general contract market in installations such as schools, airports and workshops.

 

Available in smooth and slip resistant finishes as well as other profiles and formats. This flooring confirms with recommended automotive standards and has a higher coefficient of friction to prevent slips & falls.

 

Fullchance Fire Shield is available in speckle, marble and plan finishes.

 

Fullchance Fire Shield Class 2 Fire Rated Rubber Flooring.

 
 

Technical Specification

  • Surface spread of flame to BS 476 Pt. 7

  • Smoke Test to BS 6853: 1999 D8.6

  • Smoke Toxicity Test to BS 6853:1999 B4.2

  • Fire Behavior to BS 6853:1999

  • Slip resistance to SATRA TM144

  • Slip Resistance to BS 7976-2 2002

  • Abrasion Resistance to ASTM D4060

  • Abrasion Resistance to DIN 53 516

  • Specific Gravity to DIN 53 508

  • Hardness to DIN 53 505

  • Tensile strength to DIN 53 504

  • Elongation to DIN 53 504

  • Compression Set to DIN 53 517

 

Product Availability

  • Thickness: 2mm, 2.5mm, 3mm & 4mm.

  • Rolls.

  • Available in a range of colours.

 

Typical Applications

  • Overland trains

  • Trams.

  • Fixed guidance vehicles

 

Speckles


DT SP CL-2 -001 ROYAL BLUE

DT SP CL-2 -002 SEA GREEN

DT SP CL-2 -003 MHAGONI
     

DT SP CL-2 -004 DARK GREY

DT SP CL-2-005 BLACK

DT SP CL-2 -006 LIGHT GREEN
     

DT SP CL-2 -007 SAND YELLOW

DT SP CL-2 -008 LIGHT GREY

DT SP CL-2 -009 OLIVE GREEN

On a product: Stair Treads